| ⚠️ WARNING: This article is intended for qualified professional electrical installers ONLY. System owners (consumers) should NOT follow these instructions. Improper installation or handling of electrical equipment can result in serious injury, fire, or damage to your system and loss of warranty. If you are a system owner and need assistance, please contact your Emaldo® installer directly. |
Yes, the Emaldo® system has a IP54 protection level. Please follow the instruction of the full installation manual about the enviroment requirement.
The Emaldo® Power Box (battery) works at the temperatures from -20 to 50 degrees and when the batteries reach temperatures between 0-6 degrees then the heating of the batteries will start to ensure the working temperature stays at minimum 6 degrees.
The Emaldo® Power Box are then fully operational all the time because of the build in heating control.
At temperatures below -20 degrees, Emaldo cannot guarantee that the system will not be damaged.
When the ambient temperature is over 45℃ or below -10℃, the charging and discharging power of the battery will be reduced. If the system is installed in a cold environment, the system will start the built-in thermal control system to heat the battery to obtain better performance. The heating process will consume rechargeable power, which means that the energy efficiency of the system will be reduced in a short time.
Salt-damaged area refers to the area within 500m from the coast or affected by sea breeze.